Plazmax is an Authorised Hypertherm OEM Channel Partner. We supply Duramax machine torch consumables for Plazmax cutting systems and for any other CNC table, track cutter or robotic cell running a Powermax45 XP, Powermax65, Powermax85, Powermax105 or Powermax125 power source.
This page covers the separate-part consumable stack - electrode, swirl ring, nozzle, retaining cap and shield or deflector. If your torch takes a one-piece SmartSYNC cartridge instead, you have a SYNC system: go to the Powermax SYNC page.
Pick the nozzle by the amperage you cut at, then match the shield to the process. The electrode and retaining cap are the same part right across 45 XP, 65, 85 and 105. The swirl ring is the one part that changes with the power source: 220857 on the Powermax45 XP, 65 and 85, 220994 on the Powermax105.
| Amp | Process | Shield or deflector | Retaining cap | Nozzle | Electrode | Swirl ring |
|---|---|---|---|---|---|---|
| 45 A | Shielded | 220817 | 220854 | 220941 | 220842 | 220857 (220994 on 105) |
| 65 A | Shielded | 220817 | 220854 | 220819 | 220842 | 220857 (220994 on 105) |
| 85 A | Shielded | 220817 | 220854 | 220816 | 220842 | 220857 (220994 on 105) |
| 105 A | Shielded | 220993 | 220854 | 220990 | 220842 | 220994 |
| 45 A | Shielded, ohmic | 220817 | 220953 | 220941 | 220842 | 220857 (220994 on 105) |
| 65 A | Shielded, ohmic | 220817 | 220953 | 220819 | 220842 | 220857 (220994 on 105) |
| 85 A | Shielded, ohmic | 220817 | 220953 | 220816 | 220842 | 220857 (220994 on 105) |
| 105 A | Shielded, ohmic | 220993 | 220953 | 220990 | 220842 | 220994 |
| 45 A | Unshielded | 220955 | 220854 | 220941 | 220842 | 220857 (220994 on 105) |
| 65 A | Unshielded | 220955 | 220854 | 220819 | 220842 | 220857 (220994 on 105) |
| 85 A | Unshielded | 220955 | 220854 | 220816 | 220842 | 220857 (220994 on 105) |
| 105 A | Unshielded | 220955 | 220854 | 220990 | 220842 | 220994 |
Which rows apply to your machine: a Powermax45 XP runs the 45 A rows only. A Powermax65 runs 45 A and 65 A. A Powermax85 runs 45 A to 85 A. A Powermax105 runs the lot. For the 45 XP, Hypertherm lists the shielded and ohmic sets for the machine torch; the only unshielded set listed for it is the FineCut one in the next table.
Ohmic rows use the ohmic-sensing retaining cap 220953 in place of 220854 so your torch height control can find the plate by contact. Everything else in the stack is the same.
CopperPlus electrode 220777 drops straight into any of these sets in place of 220842. Hypertherm rates it at least twice the life of the standard electrode, for cutting 12 mm and under at 40 A to 105 A. Over 12 mm, stay on 220842.
FineCut is the thin-plate set for mild steel and stainless, with its own nozzle, swirl ring and shield. Gouging and marking sets keep the standard electrode and retaining cap and change the nozzle and shield.
| Fits | Process | Shield or deflector | Retaining cap | Nozzle | Electrode | Swirl ring |
|---|---|---|---|---|---|---|
| 45 XP, 65, 85, 105 | FineCut, shielded, ohmic | 220948 | 220953 | 220930 | 220842 | 220947 |
| 45 XP, 65, 85, 105 | FineCut, unshielded | 220955 | 220854 | 220930 | 220842 | 220947 |
| 65, 85 | Gouging, Maximum Removal | 220798 | 220854 | 220797 | 220842 | 220857 |
| 105 | Gouging, Maximum Removal | 220798 | 220854 | 220991 | 220842 | 220994 |
| 65, 85 | Gouging, Maximum Control | 420480 | 220854 | 220797 | 220842 | 220857 |
| 105 | Gouging, Maximum Control | 420480 | 220854 | 220991 | 220842 | 220994 |
| 45 XP | Gouging, Maximum Control 26 to 45 A | 420480 | 220854 | 420419 | 220842 | 220857 |
| 45 XP | Precision gouging 10 to 25 A | 420414 | 220854 | 420415 | 220842 | 220857 |
| 45 XP | Marking 10 to 25 A | 420542 | 220854 or 220953 | 420415 | 220842 | 220857 |
| 45 XP | HyAccess gouging 65 A | None | 420413 | 420412 | 420408 | 220857 |
The FineCut shield 220948 is made to sit on the ohmic cap, so there is no separate standard-cap version of that set. Hypertherm does not recommend FineCut for aluminium.
Gouging: Maximum Removal takes the most metal per pass, Maximum Control gives a narrower, more controllable groove. Both use the same nozzle for a given power source. The 45 XP has its own gouging and marking nozzles at lower current, and the HyAccess set with the extended nozzle and electrode for reaching into corners and over obstructions.
The Powermax125 runs the Duramax Hyamp torch, and nothing in it crosses over from the smaller Duramax torches. Electrode 220971, retaining cap 220977 and swirl ring 220997 are common to every row below; the nozzle and shield change with amperage and process.
| Amp | Process | Shield | Retaining cap | Nozzle | Electrode | Swirl ring |
|---|---|---|---|---|---|---|
| 45 A | Shielded | 420168 | 220977 | 420158 | 220971 | 220997 |
| 65 A | Shielded | 420168 | 220977 | 420169 | 220971 | 220997 |
| 105 / 125 A | Shielded | 220976 | 220977 | 220975 | 220971 | 220997 |
| 45 A | Shielded, ohmic | 420168 | 420156 | 420158 | 220971 | 220997 |
| 65 A | Shielded, ohmic | 420168 | 420156 | 420169 | 220971 | 220997 |
| 105 / 125 A | Shielded, ohmic | 220976 | 420156 | 220975 | 220971 | 220997 |
| - | Gouging | 420112 | 220977 | 420001 | 220971 | 220997 |
| - | FineCut, shielded | 420152 | 220977 | 420151 | 220971 | 220997 |
| - | FineCut, shielded, ohmic | 420152 | 420156 | 420151 | 220971 | 220997 |
One nozzle and one shield cover both 105 A and 125 A on the Hyamp torch; you do not change parts between the two settings. Hypertherm lists no unshielded set for the Hyamp machine torch.
These parts are matched to the torch and the power source, not to the table. If your machine runs a Powermax45 XP, Powermax65, Powermax85 or Powermax105 with a Duramax or Duramax Lock machine torch, or a Powermax125 with a Duramax Hyamp machine torch, the tables above are the right parts whatever brand built the gantry, and whether the table came from us or from someone else.
Duramax retrofit torches on older Powermax systems take the same parts. The MRT retrofit machine torch on a Powermax1000, 1250 or 1650 uses the 45 A, 65 A and 85 A shielded, ohmic and unshielded sets from the first table, with the 1650 also running a 100 A set: nozzle 220990, shield 220993 and swirl ring 220994. The MRT2 retrofit torch on a Powermax600, 800 or 900 uses the 45 A sets. Match the amperage to the power source: a Powermax1000 runs 45 A to 65 A, a 1250 runs 45 A to 85 A, a 1650 runs 45 A to 100 A.
The Hyamp machine torch has a 44 mm barrel. If you are fitting a Powermax125 to a track burner, pipe cutter or older table with a 35 mm torch clamp, Hypertherm's Hyamp torch adapter kit 428495 is the mount for it. Ask us, it is not a shop line.
You can run the one-piece SmartSYNC cartridges in a Duramax torch with a cartridge torch adapter, and then the Powermax SYNC page is your parts list. There are two adapters, and they are not interchangeable:
Two things to know before you order one. The cartridge has no data connection through an adapter, so you do not get the automatic process setup or the cartridge usage tracking that a SYNC system gives you through a SmartSYNC torch; you set amperage and mode yourself, as you do now. And Hypertherm does not recommend the adapter on the Duramax retrofit torches for the Powermax1000, 1250 and 1650. For cut settings with cartridges on a Duramax machine torch, Hypertherm publishes a separate cut chart guide, 811300MU.
"*" indicates required fields