Worn consumables usually show up in the cut before you can see much wrong with the parts themselves. More dross on the bottom edge, a cut angle that starts to drift, sparks coming off the top of the plate, or an arc that will not cut all the way through are the common signs. When you see them, check your cut settings against the cut chart first, then pull the consumables and look at them. If the electrode or nozzle is worn, change both at the same time.
This guide is for mechanised Hypertherm plasma systems. It follows what Hypertherm says in its own manuals, and we have listed the documents at the bottom so you can check them yourself.
What you see on the plate, and what to check
Hypertherm's troubleshooting lists the same few causes again and again. Worn consumables are on nearly every list, but so are the settings, so rule the settings out first.
| What you see | Usual causes | Check first |
|---|---|---|
| Dross on the bottom of the cut | Cut speed wrong for the plate, arc current too low, worn or damaged consumables | Speed and amps against the cut chart, then the nozzle and electrode |
| Arc not cutting right through, lots of sparks on top | Current too low, cut speed or cut height too high, worn parts, plate too thick for the process | Cut chart settings, then the consumables |
| Cut angle not square | Wrong direction of travel, torch height, cut speed or current off the chart, torch not square to the plate, worn parts | The good side of the cut is on the right of the torch travel. Then height and settings, then the parts |
| Parts wearing out faster than usual | Cuts started or finished off the plate, settings not as per the cut chart, cutting magnetic plate | Start and finish every cut on the plate |
How to check each part
Hypertherm recommends looking over the consumables every day before you start cutting. Turn the power off first, take the torch to the edge of the table so nothing drops into the water, and lay the parts out on a clean cloth.
Electrode
The centre of the electrode is a hafnium insert, called the emitter. As it wears, a pit forms in it, and the number of arc starts and the arc-on time both add to that wear. A new electrode face is shiny and smooth. Hypertherm says to replace the electrode and nozzle when any of these show up:
- The pit has spread wider than the hafnium insert.
- The pit is lopsided with rough edges, and the face around it is rough.
- The pit is deeper than the guide for that electrode.
| Electrode amperage | Replace at a pit depth of |
|---|---|
| Under 130 A | 1 mm or more |
| 130 A to under 220 A | 1.25 mm or more |
| 220 A and above | 1.5 mm or more |
Those figures are Hypertherm's guide for XPR electrodes, from the XPR instruction manual. The MAXPRO200 manual gives 1 mm as the general guide for its electrodes. Hypertherm also points out that your own cut quality requirements may mean changing an electrode earlier or later than this.
SilverPlus electrodes run deeper before they are done. Hypertherm's consumable inspection visual aid shows a SilverPlus electrode as fully used at about 2.5 mm of pit depth, where a copper electrode is done at about 1.5 mm.
Nozzle
The hole in the centre of the nozzle must be round. Replace the nozzle if the hole has gone out of round, if there is erosion or missing material, if the gas holes are blocked, or if there are signs of arcing. Inside the nozzle, some black or grey swirl marks are normal, and any white material is hafnium oxide that cleans out easily.
Shield
Same check for the shield: the centre hole should be round. Look for erosion, missing material, blocked gas holes and molten metal stuck to it. On some systems Hypertherm says you can clean spatter off a shield cap that is otherwise undamaged. If the shield is damaged, replace it. Deep scratches or gouges on the face of the shield can mean the torch has hit the plate, so replace it and find out why.
Swirl ring
Look for chips, cracks and blocked gas holes. Blow out any dirt with clean compressed air. If it is damaged, replace it.
Retaining cap
Replace it if it is eroded, cracked or has burn marks.
O-rings
Replace any O-ring that is damaged. If they look dry, put a thin film of silicone lubricant on them. They should look shiny, but too much lubricant can block the gas flow, so wipe off any excess.
Change the electrode and nozzle together
Both the MAXPRO200 and XPR manuals say the same thing: always replace the nozzle and electrode as a set. If an electrode is being changed because of wear, the nozzle comes out with it, even if the nozzle still looks all right.
Powermax SYNC cartridges work differently
On a Powermax65, 85 or 105 SYNC there is no separate electrode and nozzle to check. The consumables come as one cartridge, and when it is done you replace the whole cartridge. Do not try to take it apart.
The system watches the cartridge for you. When it senses the cartridge is at end of life it shows fault code 0-32-0, and you fit a new one. You can change it before then if the cut quality is no longer good enough for the job. More frequent 0-30-0 faults are also normal as a cartridge nears the end. See our mechanised Powermax SYNC consumables for the cartridge range.
Things that look like worn parts but are not
- Settings off the cut chart. Wrong speed, current or cut height cause dross, bevel and poor penetration on brand new parts.
- Wet or oily air, or the wrong gas pressure. Both spoil the cut and shorten consumable life. See the air and gas supply section below.
- Starting or finishing off the plate. This pulls the arc sideways and can damage the nozzle and shield. Start and finish every cut on the plate where you can.
- The torch touching the plate. On a mechanised system the torch must not touch the plate while piercing or cutting. Contact damages the shield and nozzle and marks the cut face.
- The machine, not the torch. If the cut angle is out, Hypertherm's test is simple: make a test cut and measure the angle on each side, rotate the torch 90 degrees in its holder and do it again. If the angles come out the same both times, the problem is in the drive system, not the plasma.
Air and gas supply
Dirty, wet or oily air causes more plasma problems than most people expect. Hypertherm lists poor gas quality as a cause of worse cut quality, slower cutting, less cut thickness and shorter consumable life. For compressed air it specifies clean, dry, oil-free air to ISO 8573-1 Class 1.4.2, which means a dew point no higher than 3°C and almost no oil. The compressor must remove oil before the air reaches the cutting system.
If you cut with oxygen, Hypertherm specifies 99.5% purity, clean, dry and oil free. Nitrogen and argon have their own purity figures in your system's manual.
Pressure matters as much as quality. Gas pressure or flow outside the recommended range, or a leak in the line, spoils the cut and shortens consumable life. Set it to what the manual and cut chart say, and check the regulators and hoses if the cut changes for no obvious reason.
A Powermax has a built-in filter that catches particles down to 5 microns and some moisture. In a warm, humid workshop, or where oil can get into the line, Hypertherm recommends an extra filter before the power supply. On XPR systems with a water injection console, the shield water also has to meet Hypertherm's purity spec, because poor water leaves deposits on the nozzle and shield and makes the arc unstable.
Getting more out of each set
- Do not fire the torch into the air. Start on the plate or at its edge.
- Use the pierce height from the cut chart.
- Finish each cut with the arc still on the plate, so the system can ramp down properly.
- Where you can, chain cut from one part to the next so there are fewer arc starts and stops.
- On fast cuts, slow down near the end of the cut and run the torch into the scrap area.
- Keep the air or gas supply clean and dry.
There is no fixed life for a set of consumables. Hypertherm's XPR manual says the number of starts and the arc-on time affect electrode wear, and that your own cut quality requirements decide when to change. Keeping a simple record of when each set went in is the best guide for your own machine.
Consumables in New Zealand
Plazmax is an Authorised Hypertherm OEM Channel Partner. We hold stock of mechanised XPR, MAXPRO200, Powermax and Duramax consumables, dispatched the same business day on most items. Each family page carries Hypertherm's full mechanised tables: XPR, MAXPRO200, Powermax SYNC and Duramax, or start at our consumables page.
If you would rather have someone look at the machine, Plazmax services any Hypertherm-powered system in New Zealand, whoever built it, including 24/7 breakdown call-out. See service and support.
Frequently asked questions
How often should I check plasma consumables?
Every day before you start cutting. That is Hypertherm's recommendation for its mechanised systems, and it takes a couple of minutes.
How do I know if a plasma electrode is worn?
Look at the pit in the hafnium insert. Replace the electrode if the pit has spread past the insert, looks rough and lopsided, or is deeper than Hypertherm's guide for that amperage: 1 mm under 130 A, 1.25 mm from 130 A to under 220 A, and 1.5 mm at 220 A and above. SilverPlus electrodes can go deeper, to about 2.5 mm.
Should I change the nozzle and electrode at the same time?
Yes. Hypertherm says to always replace the nozzle and electrode as a set.
Why am I getting dross on the bottom of my cuts?
Usually the cut speed is wrong for the plate, the current is too low, or the consumables are worn. Check speed and amps against the cut chart first, then inspect the nozzle and electrode.
How long do plasma consumables last?
There is no fixed figure. Wear depends on the number of arc starts, the arc-on time and how closely the settings follow the cut chart. Starting and finishing every cut on the plate helps.
Do Powermax SYNC cartridges need any maintenance?
No. When a cartridge is worn you replace the whole thing. The system tells you when it reaches end of life with fault code 0-32-0.
Sources: Hypertherm MAXPRO200 Instruction Manual 807700 Revision 9.4 (gas requirements page 17, inspection pages 101 to 105, troubleshooting and cut quality pages 109 to 113); Hypertherm XPR460 Instruction Manual 811530 Revision 0 (gas quality and air compressor requirements page 49, shield water page 55, gas supply page 131, consumable life pages 243 to 245, inspection pages 254 to 261, troubleshooting pages 293 to 295); Hypertherm Powermax65/85/105 SYNC Operator Manual 810470 Revision 4.1 (gas supply page 55, cartridge end of life page 80, troubleshooting pages 122 to 129); Hypertherm Consumable Inspection Visual Aid 897670 Revision 4 (April 2023).